MODEL
DNDY
2-position, 6-way, solenoid-operated directional spool valve
SERIES 1 / CAPACITY: 20 L/min. / CAVITY: T-61A
X-Control
D-Control
L-Control
M or S-Control
T-Control
This solenoid-operated 6-way, 2-position cartridge is a direct-acting, balanced spool valve. The typical use for this
valve is to select between two separate circuits. The de-energized condition connects P and T to the first circuit
and when energized connects P and T to the second circuit.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 50 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 80 cc/min.@210 bar
Switching Frequency 15000 cycles/hr
Manual Override Force Requirement 33 N/100 bar @ Port 1
Manual Override Stroke 2,5 mm
Seal kit - Cartridge Buna: 990-461-007
Seal kit - Cartridge Viton: 990-461-006
(X)CONTROL
X No Manual Override
D Twist/Lock (Dual) Manual Override
L Twist/Lock (Detent) Manual Override
M Manual Override
T Twist (Momentary) Manual Override
(X)SPOOL CONFIGURATION
X -
(N)SEAL MATERIAL
N Buna-N
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
DNDY
TECHNICAL FEATURES
The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
This valve is direct actuated and requires no minimum hydraulic pressure for operation.
This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is
not compatible with weatherized coils.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control
assembly has a mechanical life expectancy of approximately 7,000 cycles.
This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a
NOTES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Model Code Example: DNDYXXNCONFIGURATION OPTIONS